Zero Electricity Cost:
- DC direct drive, high self-generation and self-consumption rate, integrated electricity can be zero
AC And DC:
- Power multi-port, to achieve DC / AC power double drive, stability is better
180 Sine Wave Control:
- 180 ° sine wave control: DC inverter compressor using 180 ° sine wave vector control technology, so that the compressor motor running smoothly, extend the service life, significantly improve energy efficiency
R32 Refrigerant:
- R32 refrigerant, GWP675, low greenhouse effect
Wide Working Range:
- Whether the temperature is as high as 52 ℃ hot summer, or as low as -15 ℃ cold winter, the outdoor unit can run smoothly, allowing you to four seasons like spring
High Operating Efficiency:
- Outdoor unit, indoor unit full DC + electronic expansion valve configuration
Specification | 24K | ||
DC INVERTER | Model | DW3B1-ACDC-24KR2 | |
System Format | 1 drive 3 | ||
Power Supply AC | V/Ph/Hz | AC208~230/1/50~60 | |
Power supply DC PV String Input Data |
Voc | DC 150-410V | |
Max. PV (DC) Input Current (A) | 13+13 | ||
Max. PV ISC (A) | 22+22 | ||
No.of MPP Trackers | 1 | ||
No.of Strings per MPP Tracker | 2 | ||
Capacity | Cooling | Btu/h | 24000(7800~27000) |
kW | 7.03(2.3~8.70) | ||
Heating | Btu/h | 24000(8400~28000) | |
kW | 7.03(2.46~9.09) | ||
Electric Data | Cooling Power Input | W | 1901(560~2468) |
Heating Power Input | W | 1674(560~2216) | |
Rated Current (cooiling) | A | 8.81 | |
Rated Current ( heating) | A | 7.76 | |
Performance | SEER/SEER2 | 22/23 | |
HSPF/HSPF2 | 11/10 | ||
EER/COP | BTU/W | 12.6/14.3 | |
Sound Pressure Noise Level | dB(A) | 58 | |
Dimension | Net (W*D*H) | mm | 888×318×700 |
Packing (W*D*H) | mm | 1006*418*755 | |
Weight | Net/Gross | kg | 46.5/52 |
Piping | Liquid Side | mm(inch) | 3×6.35(1/4) |
Gas Side | mm(inch) | 3×9.52(3/8) | |
Piping | Liquid Side | mm(inch) | 3×6.35(1/4) |
Gas Side | mm(inch) | 3×9.52(3/8) | |
Max.length for all rooms (m) | m | 60 | |
Max.length for one IDU (m) | m | 30 | |
Max.height difference between IDU and OU (m) | m | 15 | |
Max.height difference betweenIDUs (m) | m | 10 | |
Ambient Temp (Cooling/Heating) | ℃ | -10~52℃/-15~24℃ |
Specification | 7K | 9K | 12K | 18K | ||
Model | indoor | DMGA1-ACDC-07KR2 | DMGA1-ACDC-09KR2 | DMGA1-ACDC-12KR2 | DMGA2-ACDC-18KR2 | |
Capacity | Cooling | Btu/h | 7000 | 9000 | 12000 | 17100 |
kW | 2.05 | 2.64 | 3.52 | 5.01 | ||
Heating | Btu/h | 8000 | 9550 | 12300 | 17550 | |
kW | 2.35 | 2.8 | 3.6 | 5.14 | ||
Electric Data | Power Supply | V | DC 290-380V | DC 290-380V | DC 290-380V | DC 290-380V |
Cooling Power Input | W | 30 | 30 | 30 | 50 | |
Heating Power Input | W | 30 | 30 | 30 | 50 | |
Performance | Air Flow Volume | CFM | 365 | 365 | 365 | 600 |
m3/h | 620 | 620 | 620 | 1020 | ||
Sound Pressure Noise Level | dB(A) | 42.5 | 42.5 | 42.5 | 46 | |
Dimension | Net (W*H*D) | mm | 840*205*295 | 840*205*295 | 840*205*295 | 1080*330*237 |
Packing (W*H*D) | mm | 920*290*360 | 920*290*360 | 920*290*360 | 1140*362*300 | |
Weight | Net | kg | 9.5 | 9.5 | 9.5 | 15.0 |
Gross | kg | 11.8 | 11.8 | 11.8 | 17.5 | |
Pipe Diameter | Liquid Side | mm(inch) | 6.35(1/4) | 6.35(1/4) | 6.35(1/4) | 6.35(1/4) |
Gas Side | mm(inch) | 9.52(3/8) | 9.52(3/8) | 9.52(3/8) | 12.7(1/2) | |
Drainage | mm | 16.9 | 16.9 | 16.9 | 16.9 | |
Stuffing Quantity | 20/40/40H | unit |
DEYE SOLAR MULTI
SPLIT SYSTEM-HYBRID ACDC
Relevant Certification
We have our own testing laboratory and advanced and complete testing equipment to ensure the quality of our products.
![]() |
![]() |
![]() |
17 Professional R&D laboratory |
50+ R&D Elite Team |
1 National accredited testing center |
![]() |
![]() |
![]() |
100+ Related patent certification |
130000m² Plant Area |
5000+ Current Employees |
We prepare ourselves for new challenges every day.